Description

Meniere's disease may be staged based on the level of hearing loss. The staging scale was developed by the Committee on Hearing and Equilibrium of the American Academy of Otolaryngology - Head and Neck Surgery.


 

Patient selection: definite or certain Meniere's

Patient exclusion: possible or probable Meniere's

 

Data set selection: worst audiogram during the 6 month interval prior to treatment

 

The pure tone threshold at each level is measured in decibels (dB).

 

4 tones tested:

(1) 0.5 kHz

(2) 1.0 kHz

(3) 2.0 kHz

(4) 3.0 kHz

 

average pure tone threshold for the 4 tones tested =

= SUM(threshold at each tone level) / 4

 

value used for staging =

= ROUND(average pure tone threshold)

Value

Stage

<= 25 dB

1

26 - 40 dB

2

41 - 70 dB

3

> 70 dB

4

 