Description

Intracranial pressure (ICP) monitoring is useful in guiding intracranial pressure-directed therapy.


Sensor: via ventriculostomy catheter

 

Parameters:

(1) maximum ICP per hour

(2) age of patient

 

mean ICP pressure =

= SUM(max hourly ICP) / 24

 

ICP burden =

= SUM(number of max ICP readings exceed threshold)

 

Age

Threshold

infant

15 mm Hg

toddler and children

20 mm Hg

 

Interpretation:

• minimum ICP burden: 0

• maximum ICP burden: 24