web analytics

Description

Bartolacelli et al reported the CoMOD echocardiographic score for evaluating a patient with patent ductus arteriosus and suspected coarctation of the aorta. This can help to identify a patient who may have neonatal surgery to treat the coarctation. The authors are from Azienda Ospedaliero-Universitaria di Bologna.


CoMOD indicates coarctation probability model.

 

Patient selection: newborn with patent ductus arteriosus and coarctation of the aorta

 

Parameters (LSA is left subclavian artery and LCA is left common carotid artery):

(1) arch diameter between LCA and LSA (D3) in mm

(2) aortic isthmic diameter (D4) in mm

(3) bicuspid aortic valve (BAV)

(4) LCA to LSA distance in mm

(5) ventricular septal defect (VSD)

 

Parameter

Finding

Points

D3

 

-1.4697 * (D3)

D4

 

-2.3423 * (D4)

BAV

no

0

 

yes

1.4493

LCA to LSA distance

 

0.3669 * (distance)

VSD

no

0

 

yes

1.9040

 

total score =

= SUM(points for all of the parameters) + 9.6254

 

Interpretation:

• A score > 0 predicts surgery.

 

Performance:

• The area under the ROC curve is 0.94.


To read more or access our algorithms and calculators, please log in or register.