Description

Tatham et al used a score to grade a patient's technique for eye drop instillation. The authors are from University Hospital Leicester.


 

Patient selection: self-instillation of eye drops

 

Parameters:

(1) technique

(2) drop delivery

(3) contamination (touches tip to eye, eyelid or eyelashes)

(4) touches cornea

 

Technique

Drop Delivery

Contamination

Cornea

Score

good

on target with drop in eye

none

no

4

awkward

on target with drop in eye

none

no

3

awkward

on target with drop in eye

present

no

2

awkward

on target with drop in eye

present

touches cornea

1

poor

not on target, drop misses eye

none

NA

0

poor

not on target, drop misses eye

present

NA

-1

 

where:

• Touching the cornea with the bottle or dropper may be associated with corneal injury.

 